Friday, April 29, 2011

2011 NEC TOP CODE CHANGES

 

GFCI devices must be installed in a readily accessible location (This impacts ceiling garage door opener devices).

The tables in 310.15 & 16 have been rearranged. Now you have your Ambient Temperature Adjustments separated into their very own table.

Transformers now require disconnects on the primary side. Now transformers fall under very similar rules that we see for other equipment.

Tamper-resistant receptacles are now required in guest rooms and in child care facilities. This increases the TR rules in most areas now.

Neutral conductors will be required at switch points, though there are a couple of exceptions, including where conduit is the wiring method.

No Grandfathering: where replacing a receptacle that would have to be AFCI, tamper-resistant, or weather-resistant, according to the 2011 code, those types of receptacles must be used in the replacement. 

Ampacity and Conduit Fill Calculation Considerations (Dangers of Annex “C”)

Wire Ampacity and Conduit Fill Calculation

This week I want to take a minute to review our wire ampacity and conduit fill (wire fill) calculation.

There seems to be a lot of common confusion out there when it comes to wire fill. Annex "C" in the back of the 2008 NEC © is a good tool, but it can be very dangerous to use it without considering the impact of de-rating factors found in Chapter 3.

We normally use a 20 amp circuit breaker to protect #12 AWG cu wire. Annex C tables show that we can safely place a total of 16 of this size (Type THHN, THWN, or THWN-2) in a 3/4" EMT conduit. this is only for the protection of the wire from a physical stand point.

Annex C is only concerned with the protection of the wire during installation. It does NOT take the ampacity of the wire into consideration!

When de-rating wire, we begin with table 310.16 (page 147, 2008 NEC ©) and de-rate for our ambient temperature AS WELL AS the number of current carrying conductors. The de-rating table T310.15(b)(2)(a) on page 145 shows us:

"Adjustment Factors for more than Three Current carrying conductors in a Raceway or Cable"

Number of Current Carrying Conductors

% of 310.16 Values

4-6 Conductors

80%

7-9 Conductors

70%

10-20 Conductors

50%

21-30 Conductors

45%

31-40 Conductors

40%

41+ Conductors

35%

You can quickly see that in our earlier example, if we put 16, #12 THHN conductors in that 3/4" conduit, we would have to drop the circuit breaker to a 15 ampere size!

Now seriously, how many electricians in the field really do that? You understand now how dangerous the casual use of Annex "C" can be.

For all practical purposes, only 9 current carrying conductors could be placed in that conduit without having to drop the OCPD (circuit breaker) size: [T310.16 value for #12 THHW=25 Amps. 25 Amps X 70% (the de-rating for 7-9 conductors) would equal 17.5 Amps, and due to 240.3(B) we are allowed to round up to a 20A breaker.] The Cut Off point is the 10-20 conductor line that HALVES our breaker/fuse sizing.

Neutrals CAN count as Current Carrying Conductors:

The grounded conductor (neutral) can also cause confusion sometimes. It counts as a "current carrying conductor" in some cases, but not in others. If it is shared between two different phases in a multi-wire circuit, it usually does not count as a current carrier , as it only carries the unbalanced load in the circuit. [For example, a "full boat with circuits #3, #5, #7 in a 30 panel, would not usually have their neutral counted.]

Where non-linear loads are supplied however the neutrals DO count. If you have electronic fluorescent ballasts or heavy computer loads (etc...) on a shared branch circuit neutral, it will have harmonic distortions that will disrupt the cancellation of loads between phases and can actually cause larger loads on a neutral that are found on any single ungrounded phase conductor in the circuit.

If the (neutral) grounded conductor is NOT shared between phases, i.e. a single 120V single phase branch circuit, such as a general purpose receptacle outlet circuit conductor, it counts as a current carrying conductor. In this installation it carries the full load of the circuit back to the distribution point.

Two other common issues with Annex C are considerations for different sized EGC/GEC conductors, and differences between Annex C values and manual fill calculations using Chapter 9, tables 4 and 5.

The value of Annex C is a "stuff it full" value. Therefore you would have to keep in mind your additional ground wire, which is usually a smaller size than that of the phase conductors. The only way to use Annex C in this case is to always consider your EGC or GEC as a full size conductor count. A manual calculation is more accurate than Annex C and it has been this author's observation that Annex C values sometimes vary quite a bit from a manually calculated fill based on Chapter 9 tables.

All of that considered, going back to our 3/4" raceway, we could put 3 "full boats" in this raceway (3 neutrals not counted, 9 phase conductors, and 1 equipment ground) for a total of 13 conductors. This results in 3 less than our "fill amount" according to our Annex C tables. Thus, our advice is to always carefully consider your ampacity de-rating factors as required by 310.15.

(Author's Note: As evidenced by the above, an electrician would have to refer to several different tables in order to correctly and safely calculate the correct fill and ampacity values for watch and every pipe run. we are excited to provide and industry first for all our members. Electrician Testing has painstakingly prepared a custom table; available only through us, that considers ALL required factors. Everything is brought together in one quick and easy to follow chart. Contact us today to get yours, and look for our upcoming publication that will include this chart along with many, many more custom time saving tables!)

Mitchell Tolbert

Master Electrician

Thursday, April 28, 2011

Mistakes Made in the 2011 NEC Code Book

 

Here is a list of the Errata Sheet (errors) made in the first printing. If you purchased your 2011 NEC Code book within the first 4 months of release, you probably have a first edition.

This is a list of errata to the first printing of the 2011 NEC®. A first printing is indicated by the numeral 1

as the last digit in the line of number appearing at the bottom of the first page.

1. Page 70-36 110.14(C)(1): Revise 310.15(B)(6) to 310.15(B)(7)

2. Page 70-78

3. Page 70-86

Figure 230.1: Revise ‘‘Source’’ to ‘‘Serving Utility’’ and 230.49 to 230.32

230.90 Exception No. 5: Revise 310.15(B)(6) to 310.15(B)(7)

4. Page 70-102 Table 250.3: Revise 300.50(B) to 300.50(C)

5. Page 70-116 250.68(C)(2)(b): Revise to read : ‘‘By bonding the structural metal frame to one or

more of the grounding electrodes, as specified in 250.52(A)(5) or (A)(7) that comply

with 250.53(A)(2).’’

6. Page 70-129 250.180: Revise 250.190 to 250.191

7. Page 70-139 300.5(C) Exception No. 2: Revise 330.10(11) to 330.10(A)(11)

8. Page 70-148 310.10(E) Exception No. 2 (d): Revise Table 310.13(D) to Table 310.104(D)

9. Page 70-148 310.10(F): Remove deletion bullet and add second paragraph to read : ‘‘Cables rated

above 2000 volts shall be shielded.’’

10. Page 70-154 Table 310.15(B)(16): Add double asterisk to 18 AWG and 16 AWG copper

11. Page 70-178 314.16(C)(1): Revise 314.16(C)(2) to 314.16(C)(3)

12. Page 70-240 392.18(E): Revise 392.10(D) to 392.18(D)

Wednesday, April 27, 2011

Three Bulbs in One: GE’s Hybrid Halogen-CFL with an Incandescent Shape

 

Instantly bright halogen capsule sits inside an energy-saving and long-lasting compact fluorescent swirl that’s contained in an incandescent-shaped glass bulb.

“It looks like an incandescent in size and shape but it’s really three bulbs in one,” observes Kristin Gibbs, general manager of consumer marketing, GE Lighting.

“The instant brightness factor makes our new hybrid halogen-CFL more versatile than other CFLs.

It’s an optimal choice for use in hallways, stairways, kitchens, bathrooms and anywhere immediate brightness is essential. Simply flip that light switch and it’s at your service—immediately.”

These new GE CFLs offer eight times the life of incandescent bulbs (8,000 hours vs. 1,000 hours). The new products — 15- and 20-watt GE Energy Smart® Soft White (2700 Kelvin) and Reveal® (2500 Kelvin) CFLs with exceptionally low levels of mercury that can replace standard 60- and 75-watt incandescent bulbs or other CFLs that don’t offer a satisfactory quality of light or instant brightness.

http://www.genewscenter.com/Press-Releases/Three-Bulbs-in-One-GE-s-Hybrid-Halogen-CFL-with-Incandescent-Shape-Arrives-in-April-2f9c.aspx

Wednesday, April 13, 2011

Handy Calculators

I was doing some research and found some great calculators online that you can use for the field.

Concrete Materials Calculators
http://www.concrete.com/calculators/concrete-materials-calculators

and


Cubic Inches to Cubic Yards converter

Cubic Inches to Cubic Yards
provided by www.metric-conversions.org


ENJOY!

Popular Posts